• Open Access
    Systematic Review

    A systematic review of DDH screening practices in the UK

    Nicholas Birkett *
    Edward Karam
    David Ferguson
    Deepika Pinto
    Claudia Maizen

    Explor Musculoskeletal Dis. 2024;2:181–188 DOI: https://doi.org/10.37349/emd.2024.00047

    Received: December 14, 2023 Accepted: January 17, 2024 Published: June 03, 2024

    Academic Editor: Fernando Pérez-Ruiz, Cruces University Hospital, Spain

    This article belongs to the special issue Baby Hip Sonography Worldwide: Experience, Results, and Recommendations

    Abstract

    Background:

    The United Kingdom (UK) currently employs a selective screening system for developmental dysplasia of the hip (DDH). Despite this, late presentation rates remain high. The aim of this study was to systematically review the available literature to gain an understanding of screening practices throughout the UK.

    Methods:

    A systematic review was conducted. Studies reporting DDH screening methods from the UK were included. The primary outcome measure was the method of ultrasound and clinical screening. Secondary outcomes were the treatment rate and late presentation rate. A narrative analysis was undertaken, as meta-analysis was felt to be inappropriate due to the differences between included studies.

    Results:

    Nine studies were eligible and included. There was significant variability in practice, with a variety of ultrasound techniques being used and a variety of staff members performing clinical screening. Treatment rate ranged from 16.4/1,000 to 0.8/1,000. Late presentation rate ranged from 1.28/1,000 to 0.27/1,000.

    Discussion:

    In spite of a national consensus statement, there is no standardised approach to clinical or ultrasound screening in the UK. A variety of different methods are used, which may explain the persistently high late presentation rate. A national system of quality control and a standardised screening process is recommended, with specialised training in the Graf method of ultrasound.

    Keywords

    DDH, screening, ultrasound, clinical screening

    Introduction

    Rationale

    Developmental dysplasia of the hip (DDH) is the most common orthopaedic disorder in newborns and is the leading cause of early-onset arthritis and total hip arthroplasty in young patients [1, 2]. Early detection and treatment of DDH can reduce the need for invasive surgical intervention and reduce long-term disability. Effective DDH screening is therefore essential to identify and treat cases as early as possible.

    At present, the United Kingdom (UK) uses a selective screening model, with children with specific risk factors (breech presentation, multiple births, family history) or an abnormal clinical examination being invited for ultrasound screening. Clinical examination is performed at birth and repeated at 6–8 weeks in a primary care setting [3].

    In 2022 the British Society for Children’s Orthopaedic Surgery (BSCOS) released a consensus statement regarding the management of DDH in the first three months of life [4]. They advocate for universal screening, but they also gave recommendations for selective screening within the current UK system. They recommend that the current risk factors be increased to include non congenital talipes equinovarus (CTEV) foot deformities and packaging disorders. They recommend that ultrasound should take place in a one-stop clinic, and that the Graf criteria of quality assurance should be adhered to. Those with clinical abnormalities on examination should have a scan within 2 weeks, and the examination itself should be performed by “expert” examiners with robust methods of quality assurance in place.

    Objectives

    This paper aims to evaluate screening in the UK by performing a systematic review of the relevant literature. This will provide an overview of the screening methodologies used. It can then be evaluated whether UK practice reflects that of the BSCOS consensus statement.

    Materials and methods

    A Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) compliant systematic review was conducted to gain an overview of current screening practice in the UK [5]. The Embase and Medlin databases were searched, along with the Cochrane Library.

    Eligibility criteria

    Study designs

    Unpublished studies, guidelines, protocols, and editorials were not considered. Previous systematic reviews were also excluded. All other study designs were considered.

    Types of participants

    Exclusion criteria included studies with either serious or critical risk of bias.

    Interventions

    Interventions eligible for consideration were children who had undergone ultrasound screening for DDH in the UK. A full list of inclusion and exclusion criteria is detailed in Table 1.

    Full inclusion and exclusion criteria

    Selection criteriaInclusion criteriaExclusion criteria
    LanguageEnglish languageNon-English studies
    Study typeAll study designsSystematic reviews
    PopulationNewborn population
    Human studies
    UK based study
    Children older than newborn
    Cadaveric or animal studies
    Non-UK study
    InterventionDDH screeningNot relevant to screening
    DateStudies after 2009Studies prior to 2010
    QualityClearly reported methodologySerious or critical risk of bias
    AvailabilityFull text availableAbstract only available
    Unpublished studies
    Editorials
    Display full size

    Outcomes of interest

    The primary outcome measures of interest were the methods of ultrasound and clinical screening used. Secondary outcomes were the treatment rate and late presentation rate. The search strategy is detailed in Figure 1.

    PRISMA flow diagram illustrating literature search. n: number. RCTs: randomized controlled trials; ROBINS-I: risk of bias in non-randomized studies of interventions

    Search strategy

    A systematic literature search was performed. The Embase, Medline, and PubMed databases, along with the Cochrane Library were searched. The search strategies and results are presented in Figure 1.

    Selection process

    The resulting papers were then manually searched to determine whether they met the inclusion criteria (Table 1). This was performed independently by 2 authors (Nicholas Birkett and Edward Karam). In the case of only one author including a paper, it was included in the review nonetheless.

    Data collection process and synthesis methods

    The methodologies and data extracted were reviewed. Meta-analysis was felt to be inappropriate due to the heterogeneity in both treatment modalities and outcome measurements. A narrative review was conducted to best answer the research question.

    Risk of bias assessment

    The ROBINS-I critical appraisal tool was used to evaluate the included studies for risk of bias [6]. The studies were then categorised as either low, moderate, serious, or critical risk.

    Results

    Study selection

    A total of 1,730 studies were identified from the literature search (Medline, Embase, PubMed, and Cochrane Library). Ninety one studies were selected for full-text review following assessment of their abstracts. Of these, 9 met the inclusion criteria and were deemed eligible for this review. The full results of the literature search are presented in Figure 1.

    Risk of bias in studies

    The critical appraisal is summarised in Table 2, assessed using the ROBINS-I tool. The studies were all low or moderate risk.

    Assessed risk of bias of included studies using the ROBINS-I tool

    StudyType of biasOverall bias risk
    ConfoundingSelection of participantsClassification of interventionDeviations from intended interventionsMissing dataMeasurement of outcomesSelection of reported results
    Afaq et al. [7]ModerateModerateModerateLowModerateLowLowModerate
    Broadhurst et al. [8]LowLowLowLow LowLowLowLow
    Choudry et al. [9]LowLowLowLowModerateLowLowModerate
    Clarke et al. [10]LowLowModerateLowLowModerateLowModerate
    Donnelly et al. [11]LowLowLowLowLowLowLowLow
    McAllister et al. [12]LowLowLowLowLowLowLowLow
    Talbot et al. [13]LowLowModerateLowLowLowLowLow
    Tyagi et al. [14]LowModerateLowLowLowLowLowModerate
    Westacott et al. [15]LowLowLowModerateModerateModerateLowLow
    Display full size

    Findings

    The included studies highlighted the variability in screening practice throughout the UK, with a variety of reported clinical and ultrasound screening methods. All papers reported on selective screening, except for Westacott et al. [15], whose study compared universal with selective screening.

    Primary outcome—ultrasound and clinical screening method

    The ultrasound screening method was reported in 7/9 (78%) of papers. Five studies used either the Graf technique or a modification of it. Other methods used were Harcke, Terjesen, and Clarke. Often, these methods were combined and modified.

    There was significant variability in the healthcare professional performing the ultrasound screening. Four studies did not report who performed the ultrasound screening. Other papers reported screening being performed by orthopaedic consultants, radiologists, sonographers, and physiotherapists. It is unclear from the papers whether these staff members had specific training or not.

    Clinical examination was performed by a wide variety of staff. Most commonly, the examination was performed by either midwives or junior doctors in paediatrics. Other studies reported examinations by orthopaedic surgeons, physiotherapists, paediatricians, and health visitors.

    Risk factors that prompted screening generally conformed with the UK newborn and infant physical examination (NIPE) guidelines [3]. Westacott et al. [15] included packaging disorders and non-CTEV foot disorders as risk factors.

    Secondary outcomes

    Treatment rates ranged from 16.4/1,000 to 0.8/1,000. The highest treatment rate was seen in the universal screening group in Westacott et al. [15], which is to be expected. Late presentation rates were poorly reported but ranged from 1.28/1,000 to 0.27/1,000. The definition of late presentation varied by study which made direct comparison difficult. It is worth noting that Westacott et al. [15] found 5 cases of delayed presentation in both their universal and selective screening groups, but all the cases in the universal group were due to administrative errors.

    A summary of all the studies’ findings can be found in Table 3.

    A summary of included studies and result

    StudyNumber of patientsUS methodProfessional performing USProfessional performing clinical examCriteria for referralTreatment rateLate presentation rate
    Afaq et al. [7]200Harcke method with Terjesen measurementsConsultant radiologist or sonographerJunior doctor or midwifeFamily history, breech, syndromic children, spinal or foot deformities, abnormal examinationNot reportedNot reported
    Broadhurst et al. [8]3,635Not reportedNot reportedNot reportedFamily history, breech presentationNot reported1.28/1,000
    Choudry et al. [9]124Graf & HarckeOrthopaedic consultantVariable—junior doctor/midwife/advanced nurse practitionerFamily history, breech presentation, abnormal examination0.8/1,0000.78/1,000
    Clarke et al. [10]20,344ClarkeNot reportedPaediatricianFamily history, breech presentation, foot deformities, abnormal examination7.2/1,0000.34/1,000
    Donnelly et al. [11]75,856GrafNot reportedHealth visitorsFamily history, breech presentation, abnormal examination8.5/1,0000.42/1,000
    McAllister et al. [12]896,594Not reportedPhysiotherapist/PhysicianPhysiotherapist/PhysicianFamily history, breech presentation, moulding abnormality, abnormal examinationNot reportedNot reported
    Talbot et al. [13]2,984Modified Harcke (dynamic) & modified Graf (static)Not reportedOrthopaedic surgeonFamily history, abnormal examination16.4/1,000Not reported
    Tyagi et al. [14]3,618GrafConsultant radiologist/radiographerMaternity care professionalFamily history, breech, multiple pregnancies, CTEV, high bodyweight females, abnormal examination3.31/1,0000.27/1,000
    Westacott et al. [15] (selective group)18,053GrafRadiographer or orthopaedic consultantJunior doctor or general practitionerFamily history, breech presentation, multiple pregnancies, increased birth weight, non-CTEV foot deformities, packaging disorders2.3/1,0000.28/1,000
    Westacott et al. [15] (universal group)10,015GrafRadiographer or orthopaedic consultantN/A—US screening aloneN/A—universal7.9/1,0000.5/1,000
    Display full size

    N/A: not applicable; US: ultrasound

    Discussion

    The included studies highlight the variability in DDH screening practice throughout the UK. Criteria for screening appear relatively similar and in keeping with NIPE guidelines, but work is required to expand the indications to include foot deformities and packaging disorders as per the BSCOS consensus statement. Most variability was noticed in ultrasound methodology and in the seniority or experience of those carrying out clinical examinations. It is clear from many of the studies that the important task of clinical examination is often carried out by a relatively inexperienced member of the team.

    The late presentation rate of DDH in the UK has been estimated at 1.2/1,000 [16]. Countries with universal screening have reported late presentation rates ranging from 0 to 0.16/1,000 [17, 18]. The introduction of selective screening in the UK did not have any effect on late presentation rates, highlighting inconsistency in practice [8]. If the current system of selective screening in the UK is to continue for the foreseeable future, consistency and quality control are required at all levels of the process, from the initial assessment of the newborn to the ultrasound screening itself.

    One essential area for improvement is education and training in the Graf method of ultrasound. The method is recommended but is often implemented in a modified fashion. The Graf method is successful when performed with the correct technique and the strict reporting criteria are adhered to. Modifications of the Graf method invalidate its efficacy, therefore widespread training in how to properly apply the method is required.

    In conclusion, despite a national consensus statement, the UK literature demonstrates significant variability in practice. Significant change is required at a national level to standardise screening processes, with a national level of quality control to ensure that the highest quality care is being delivered. Specific training in the Graf ultrasound method is recommended, to ensure it is delivered correctly without modification.

    Abbreviations

    BSCOS:

    British Society for Children’s Orthopaedic Surgery

    CTEV:

    congenital talipes equinovarus

    DDH:

    developmental dysplasia of the hip

    ROBINS-I:

    risk of bias in non-randomized studies of interventions

    Declarations

    Author contributions

    NB: Conceptualisation, investigation, writing—original draft preparation, Writing—review & editing. EK: Conceptualisation, investigation, Writing—review & editing. DF and DP: Investigation, Writing—review & editing. CM: Conceptualisation, supervision, Writing—review & editing. All authors read and approved the submitted version.

    Conflicts of interest

    The authors declare that they have no conflicts of interest.

    Ethical approval

    Not Applicable.

    Consent to participate

    Not Applicable.

    Consent to publication

    Not Applicable.

    Availability of data and materials

    All data is from studies referenced in the manuscript.

    Funding

    Not Applicable.

    Copyright

    © The Author(s) 2024.

    References

    Engesæter IØ, Lehmann T, Laborie LB, Lie SA, Rosendahl K, Engesæter LB. Total hip replacement in young adults with hip dysplasia. Acta Orthop. 2011;82:14954. [DOI] [PubMed] [PMC]
    Dezateux C, Rosendahl K. Developmental dysplasia of the hip. Lancet. 2007;369:154152. [DOI] [PubMed]
    Newborn and infant physical examination screening: standards [Internet]. [Cited 2023 Dec 2]. Available from: https://www.gov.uk/government/publications/newborn-and-infant-physical-examination-screening-standards
    Regarding the management of developmental dysplasia of the hip (DDH) in the first three months of life [Internet]. BSCOS; c2022 [cited 2023 Dec 8]. Available from: https://www.bscos.org.uk/consensus/consensus/DDH.php
    Moher D, Liberati A, Tetzlaff J, Altman DG; PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Ann Intern Med. 2009;151:2649. [DOI] [PubMed]
    Sterne JA, Hernán MA, Reeves BC, Savović J, Berkman ND, Viswanathan M, et al. ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ. 2016;355:i4919. [DOI] [PubMed] [PMC]
    Afaq AA, Stokes S, Fareed H, Zadeh HG, Watson M. Ultrasound in the selective screening of developmental dysplasia of the hip. Eur Rev Med Pharmacol Sci. 2011;15:3948. [PubMed]
    Broadhurst C, Rhodes AML, Harper P, Perry DC, Clarke NMP, Aarvold A. What is the incidence of late detection of developmental dysplasia of the hip in England? Bone Joint J. 2019;101-B:2817. [DOI] [PubMed]
    Choudry QA, Paton RW. Neonatal screening and selective sonographic imaging in the diagnosis of developmental dysplasia of the hip. Bone Joint J. 2018;100-B:80610. [DOI] [PubMed]
    Clarke NM, Reading IC, Corbin C, Taylor CC, Bochmann T. Twenty years experience of selective secondary ultrasound screening for congenital dislocation of the hip. Arch Dis Child. 2012;97:4239. [DOI] [PubMed]
    Donnelly KJ, Chan KW, Cosgrove AP. Delayed diagnosis of developmental dysplasia of the hip in Northern Ireland: can we do better? Bone Joint J. 2015;97-B:15726. [DOI] [PubMed]
    McAllister DA, Morling JR, Fischbacher CM, Reidy M, Murray A, Wood R. Enhanced detection services for developmental dysplasia of the hip in Scottish children, 1997–2013. Arch Dis Child. 2018;103:10216. [DOI] [PubMed] [PMC]
    Talbot CL, Paton RW. Screening of selected risk factors in developmental dysplasia of the hip: an observational study. Arch Dis Child. 2013;98:6926. [DOI] [PubMed]
    Tyagi R, Zgoda MR, Short R. Targeted screening of hip dysplasia in newborns: experience at a district general hospital in Scotland. Orthop Rev (Pavia). 2016;8:6640. [DOI] [PubMed] [PMC]
    Westacott DJ, Butler D, Shears E, Cooke SJ, Gaffey A. Universal versus selective ultrasound screening for developmental dysplasia of the hip: a single-centre retrospective cohort study. J Pediatr Orthop B. 2018;27:38790. [DOI] [PubMed]
    Poacher AT, Hathaway I, Crook DL, Froud JLJ, Scourfield L, James C, et al. The impact of the introduction of selective screening in the UK on the epidemiology, presentation, and treatment outcomes of developmental dysplasia of the hip. Bone Jt Open. 2023;4:63542. [DOI] [PubMed] [PMC]
    Biedermann R, Riccabona J, Giesinger JM, Brunner A, Liebensteiner M, Wansch J, et al. Results of universal ultrasound screening for developmental dysplasia of the hip. Bone Joint J. 2018;100:1399404. [DOI] [PubMed]
    Andersson JE. Neonatal hip instability: results and experiences from ten years of screening with the anterior-dynamic ultrasound method. Acta Paediatr. 2002;91:9269. [DOI] [PubMed]